Example 9: Pass/Fail Test


In Pass/Fail Test, the oscilloscope compares the input signal to the established
waveform mask.

Execute the steps as following:


1. Press Utility→Pass/Fail.
2. Press Enable Test and select ON.
3. Press Mask Setting and then:

Press Recall to a the saved mask or press X Mask and Y Mask to adjust the
horizontal limit and vertical limit with the multifunctional knob then press
Create Mask to create a new mask.

4. Press Output to select the output condition: pass or fail and whether sound is

included.

5. Press Operate to start the test.
6. Press Msg Display and select “ON” or “OFF”. When “ON” is selected, the test

results would be displayed at the upper left corner of the screen.