Table 2-88 The Cursor usage

Cursor

Operation

Cursor A Turn the multifunctional knob ( ) to move cursor A horizontally.

Cursor B Turn the multifunctional knob ( ) to move Cursor B horizontally.

NOTE: Moving cursor horizontally is not allowed when other (not tracking cursor)
menu is activated.

4. To get measurement values:

Position of Cursor A: Time cursor centered on the midpoint of screen; Voltage
cursor centered on channel ground level.
Position of Cursor B: Time cursor centered on the midpoint of screen; Voltage
cursor centered on channel ground level.
Read the horizontal space between Cursor A and B (

X): Time between cursors,

units in seconds. (1/

X), units in Hz, kHz, MHz, GHz

Vertical space between cursor A and B (

Y): Voltage between cursors, units in V.