RIGOL DS1000B User Manual
Page 129

RIGOL
User’s Guide for DS1000B Series
2-99
Press Measure→Time button, and go to the following menu
Figure 2-136 Table 2-82 The Time Measurement menu (Page 1/3)
Menu
Settings
Comments
Period
Measure Period of a waveform.
Freq
Measure Frequency of a waveform.
Rise time
Measure Rise Time of a rising edge.
Fall time
Measure Fall Time of a falling edge.
Figure 2-137 Table 2-83 The Time Measurement menu (Page 2/3)
Menu
Settings
Comments
+Width
Measure +Pulse Width of a pulse wave.
-Width
Measure –Pulse Width of a pulse wave.
+Duty
Measure +Duty Cycle of a pulse wave.
-Duty
Measure –Duty Cycle of a pulse wave.
Figure 2-138 Table 2-84 The Time Measurement menu (Page 3/3)
Menu
Settings Comments
Delay A→B
Measure the signals delay between
two channels at the rising edge.
Delay A→B
Measure the signals delay between
two channels at the falling edge.
Phase A B
Measure the phase difference
between two channels at the rising
edge
Phase A B
Measure the phase difference
between two channels at the falling
edge