Auto-Set functions

When the Auto is pressed the oscilloscope is configured to the following defaults:

Table 2-91 The Auto menu

Menu

Settings

Display format

Y-T

Acquire mode

Normal

Vertical Position

Adjusted to right position

Vertical “V/div”

Adjusted to right scale

Volts/Div

Coarse

Bandwidth limit

Full

[1]

Signal Invert

OFF

Horizontal position

Center

Horizontal “S/div”

Adjust to right position.

Trigger type

Edge

Trigger source

Find the channel with input signal automatically.

Trigger coupling

DC

Trigger voltage

Midpoint setting

Trigger mode

Auto

NOTE:
[1] The Bandwidth limit will turn on automatically as soon as measuring small signal.

Run/Stop: Run or Stop waveform acquiring.


NOTE: In Stop status, the volts/div and horizontal time base can be adjusted in a
fixed limit. That is, to zoom in/out the signal in vertical and horizontal directions.

Single:
When running, press this key to stop the oscilloscope, when stopped, press
this key to make a single acquisition when the trigger occurs, then stop.