beautypg.com

Waveform:yincrement, Waveform:yorigin – RIGOL DS1000B User Manual

Page 86

background image

RIGOL

Command Systems

Programming Guide for DS1000B Series

2-74

Yor: vertical offset relative to YREF;
Yref: Y reference, the middle point of the screen.

Example:

+1,+0,0,+1,8.000e-009,-6.000e-006,+0,4.000e-002,0.000e000,+100



7. :WAVeform:YINCrement?

Command Format:
:WAVeform:YINCrement? []

Function:
This command queries the Y unit voltage of the specified source. can
be: CHANnel1, CHANnel2, CHANnel3, CHANnel4 or MATH.

NOTE: returned value= VoltScale /25


Returned Format:
The query returns Y unit voltage, and the unit is V.

Example:
:WAV:YINC? CHAN2 Return 4.000e000.



8. :WAVeform:YORigin?

Command Format:
:WAVeform:YORigin? []

Function:
The command queries the vertical offset of specified source. The may
be CHANnel1, CHANnel2, CHANnel3, CHANnel4 or MATH.

Returned Format:
The query returns the value of vertical offset, and the unit is V.

Example:
:WAV:YOR? CHAN2 Return -1.600e001.