7. :MEASure:VBASe?

Command Format:
:MEASure:VBASe? []

Function:
The command measures the base value of signal from . The
may be CHANnel1, CHANnel2, CHANnel3 or CHANnel4.

Returned Format:
The query returns as -2.640e000, and the unit is V.


8. :MEASure:VAVerage?

Command Format:
:MEASure:VAVerage? []

Function:
The command measures the average value of signal from . The
may be CHANnel1, CHANnel2, CHANnel3 or CHANnel4.

Returned Format:
The query returns as -4.200e-003, and the unit is V.



9. :MEASure:VRMS?

Command Format:
:MEASure:VRMS? []

Function:
The command measures the root mean square of signal from . The
may be CHANnel1, CHANnel2, CHANnel3 or CHANnel4.

Returned Format: