beautypg.com

Trigger:level, Trigger:sweep – RIGOL DS1000B User Manual

Page 41

background image

Command Systems

RIGOL

Programming Guide for DS1000B Series

2-29

Example:
:TRIG:EDGE:SOUR CHAN1 Set the edge trigger source as channel 1.
:TRIG:EDGE:SOUR?

Return CH1.

3. :TRIGger:LEVel

Command Format:
:TRIGger:LEVel [,]
:TRIGger:LEVel? [,]

Function:
The command sets the voltage level of Edge, Pulse or Video trigger.
may be :EDGE, :PULSe or :VIDEO or :PATTern.
range: (- 6*Scale-Offset

) ~(+6*Scale+Offset

).

Scale is the current vertical scale, and the unit is V/div.

 In PATTern mode, should be set to CHANnel or EXT.

NOTE: Trigger Level range is up to+/-6 Scale, when channel has offset, it needs to detract
offset ,such as 1V tap position, 1V offset, the trigger range is -7V~5V.

Returned Format:
The query returns the value of voltage level, and the unit is V.

Example:
:TRIG:EDGE:LEV 2 Set the trigger level as 2V.
:TRIG:EDGE:LEV?

Return 2.000e000.

4. :TRIGger:SWEep

Command Format:
:TRIGger:SWEep {AUTO|NORMal|SINGle}
:TRIGger:SWEep?

Function:
The command sets the trigger mode. The may be :EDGE, :PULSe
or :PATTern.

AUTO: When no trigger is existing, the system will generate a trigger signal
to force trigger;