beautypg.com

Key:ch3_volt_z, Key:ch3_pos_inc, Key:ch3_pos_dec – RIGOL DS1000B User Manual

Page 104: Key:ch3_pos_z

background image

RIGOL

Command Systems

Programming Guide for DS1000B Series

2-92

Function:
The command increases the vertical scale of channel 3.


48. :KEY:CH3_VOLT_Z

Command Format:
:KEY:CH3_VOLT_Z

Function:
The command sets the adjustment mode of vertical scaling of channel 3 as Fine
or Coarse. The vertical scale steps by 1-2-5 in Coarse; and by equality in Fine.



49. :KEY:CH3_POS_INC

Command Format:
:KEY:CH3_POS_INC

Function:
The command increases the vertical offset of channel 3 evenly.



50. :KEY:CH3_POS_DEC

Command Format:
:KEY:CH3_POS_DEC

Function:
The command decreases the vertical offset of channel 3 evenly.


51. :KEY:CH3_POS_Z

Command Format:

:KEY:CH3_POS_Z

Function:
The command adjusts the vertical offset of channel 3 to zero.