Function:
The command sets the AY position of manual cursor. The range is
4~194.

Returned Format:
The query returns the value of AY position.

Example:
:CURS:MANU:CURAY 100 Set the AY position of manual cursor as 100.
:CURS:MANU:CURAY?

Return 100.


6. :CURSor:MANUal:CURBX

Command Format:
:CURSor:MANUal:CURBX
:CURSor:MANUal:CURBX?

Function:
The command sets the BX position of manual cursor. The range is
4~297.

Returned Format:
The query returns the value of BX position.

Example:
:CURS:MANU:CURBX 100

Set the BX position of manual cursor as 100.

:CURS:MANU:CURBX? Return 100.


7. :CURSor:MANUal:CURBY

Command Format:
:CURSor:MANUal:CURBY

Function:
The command sets the BY position of manual cursor. The range is
4~194.