beautypg.com

Measure:ndutycycle, Measure:pdelay, Measure:ndelay – RIGOL DS1000B User Manual

Page 76

background image

RIGOL

Command Systems

Programming Guide for DS1000B Series

2-64

19. :MEASure:NDUTycycle?

Command Format:
:MEASure:NDUTycycle? []

Function:
The command measures the negative duty cycle of signal from . The
may be CHANnel1, CHANnel2, CHANnel3 or CHANnel4.

Returned Format:
The query returns as 5.000e001, and the unit is %.



20. :MEASure:PDELay?

Command Format:
:MEASure:PDELay? [,]


Function:
The command measures the delay between and relative
to the rising edge. The may be CHANnel1, CHANnel2, CHANnel3 or
CHANnel4.

Returned Format:
The query returns as <-1.000 e-004, and the unit is s.


21. :MEASure:NDELay?

Command Format:
:MEASure:NDELay? [,]


Function:
The command measures the delay between and relative
to the falling edge. The may be CHANnel1, CHANnel2, CHANnel3 or
CHANnel4.

Returned Format:
The query returns as <-1.000 e-004, and the unit is s.