Setting numeric values, Reset menu ( reset ), Control menu ( contrl ) – Precision Digital PD6000 User Manual
Page 31

Model PD6000 Analog Input Process Meter Instruction Manual
31
Setting Numeric Values
The numeric values are set using the Right and Up arrow buttons. Press 
Right arrow to select next digit and Up arrow to increment digit value. 
The digit being changed is displayed brighter than the rest. 
Press the Enter button, at any time, to accept a setting or Menu button 
to exit without saving changes. 
Increment Digit
Value
Select Next Digit
Accept Setting
0
0
4.000
dis 1
00
4.
000
dis 1
Next
Setting
00
5.
000
dis 1
Note: The decimal point is set in the Setup-decimal point menu.
Reset Menu (reset)
The Reset menu is used to reset the maximum or minimum reading 
(peak or valley) reached by the process; both may be reset at the same 
time by selecting “reset high & low” (rst HL). 
Control Menu (Contrl)
The Control menu is used to control the 4-20 mA analog output and the 
relays manually, ignoring the input. Each relay and analog output can 
be programmed independently for manual control. Selecting automatic 
control sets all relays and analog output for automatic operation. 
A ou t
m a n
C o n t r l
r l y 8
m a n
r l y 1
m a n
 a u t o
 
c o n t r l
 m a n
 
c o n t r l
1
6
.0 0 0
A o u t
o n
r l y 8
o F F
r l y 1
Once Manual mode is initiated on any relay or 
analog output, an LED labeled “M” is turned 
on. Every few seconds, all LEDs representing 
outputs that are in Manual mode, as well as 
the “M” LED flash. This process will continue 
as long as any output is in manual mode. 