Front panel buttons and status led indicators – Precision Digital PD6000 User Manual
Page 26
Model PD6000 Analog Input Process Meter Instruction Manual
26
Front Panel Buttons and Status LED Indicators
Button
Symbol
Description
LED
Status
Menu
1-8
Alarm 1-8 indicator
Right arrow/F1
1-8-M
Flashing: Relay in
manual control mode
Up arrow/F2
M
Manual control relays
&/or analog output
Enter/F3
1-4
Flashing: Relay inter-
lock switch open
Note:
Alarms 5-8 are enabled when
relay expansion module is
installed.
Note:
LEDs for relays in manual mode
flash with the “M” LED every 10
seconds.
Press the Menu button to enter or exit the Programming Mode at
any time.
Press the Right arrow button to move to the next digit during digit or
decimal point programming.
Press the Up arrow button to scroll through the menus, decimal
point, or to increment the value of a digit.
Press the Enter button to access a menu or to accept a setting.
Press and hold the Menu button for three seconds to access the
advanced features of the meter.