Front Panel Buttons and Status LED Indicators
Button 
Symbol 
Description
LED
Status
Menu
1-8
Alarm 1-8 indicator
Right arrow/F1
1-8-M
Flashing: Relay in 
manual control mode 
Up arrow/F2
M
Manual control relays 
&/or analog output 
Enter/F3
1-4
Flashing: Relay inter-
lock switch open 
Note: 
Alarms 5-8 are enabled when 
relay expansion module is 
installed. 
Note: 
LEDs for relays in manual mode 
flash with the “M” LED every 10 
seconds.
Press the Menu button to enter or exit the Programming Mode at 
any time. 
Press the Right arrow button to move to the next digit during digit or 
decimal point programming. 
Press the Up arrow button to scroll through the menus, decimal 
point, or to increment the value of a digit. 
Press the Enter button to access a menu or to accept a setting.
Press and hold the Menu button for three seconds to access the 