Installation and fitting

Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited

3. INSTALLATION AND ASSEMBLY

3.1.

DRAWINGS AND TECHNICAL CHARACTERISTICS

POWERTHERM

TECHNICAL CHARACTERISTICS

Overall thermal power
Max.

10.5 kw / 9.030

kcal/h

Overall thermal power
Min.

2.6 kw / 2.236 kcal/h

Yield at maximum

91.7 % (> 90%)

Yield at minimum

92.6 % (> 90%)

Temperature of exhaust
smoke at maximum

180°C

Temperature of exhaust
smoke at minimum

70°C

CO at 13%O

²

at Min and

at Max

0.042 — 0.019%

CO

2

at minimum and

maximum

4.3% – 8.5%

Mass of smoke at
minimum and maximum

4.0 – 8.3 g/sec

Minimum draught at
maximum power

0,10 mbar – 10 Pa

Minimum draught at
minimum power

0,05 mbar – 5 Pa

Hopper capacity

26 litri

Fuel pellet type

Pellet Ø 6-8 mm.

Pezzatura 5/30 mm

Pellet consumption per
hour

Min ~ 0,6 kg/h *

Max.~ 2,2 kg/h *

Operating time between
re-fuelling

Al min ~ 28 h *

Al max. ~ 8 h *

Heatable volume m

3

226/40 – 258/35 –

301/30 **

Combustion air inlet

Ø 50 mm.

Smoke outlet

Ø 80 mm.

Maximum absorbed
electrical power

Max 420 Watt

Med 100 Watt

Power supply frequency
and voltage

220 Volt / 50 Hz

Net weight

170 Kg.

Weight with packaging

190 Kg.

Note

* Data that may vary depending on the type of pellets used.

**Heatable volume based on demand of cal/m

3

40-35-30 (respectively 40-35-30 Kcal/h for m

3

)

Appliance suitable for installation in a shared flue.