beautypg.com

MCZ Philo User Manual

Page 42

background image

PELLET STOVES

Chapter 8

USE AND MAINTENANCE MANUAL

page

42

Maintenance and cleaning

Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited

8.2.2. Decommissioning (end of season)

At the end of every season it is advisable to remove all pellets from the

tank using a vacuum cleaner with a long pipe before switching off the

stove.
During periods in which the stove is not used it must be

disconnected from the electrical supply. For increased safety,

particularly if children are present, we recommend that you

remove the power supply cable.
If, when restarting the stove at the general switch at the rear of the

stove, the control panel display is not turned on, this means the service

fuse may need replacing.
There is a fuse box on the side of the stove, beneath the electricity

socket. Using a screwdriver, open the cover on the fuse box and

replace the fuses if necessary (3.15 A delayed).

8.3. Checking the internal components

CAUTION!
The internal electrical-mechanical components must

only be checked by qualified personnel with technical

expertise in combustion and electricity.

It is advisable to perform this routine annual maintenance (with a

scheduled service contract) focusing on the visual and functional check

of the internal components:
Below is a summary of the indispensable checks and/ or servicing tasks

for the stove to function correctly.

PARTS/ PERIOD

1 DAY

2-3 DAYS

30 DAYS

90 DAYS

1 YEAR

Brazier

Ash collection

t

t

Ash tray

Glass

Complete exchanger

Smoke duct

Door seal

Air filter

Remote control battery

(if purchased/

optional)