MCZ Philo User Manual
Page 42

PELLET STOVES
Chapter 8
USE AND MAINTENANCE MANUAL
page
42
Maintenance and cleaning
Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited
8.2.2. Decommissioning (end of season)
At the end of every season it is advisable to remove all pellets from the
tank using a vacuum cleaner with a long pipe before switching off the
stove.
During periods in which the stove is not used it must be
disconnected from the electrical supply. For increased safety,
particularly if children are present, we recommend that you
remove the power supply cable.
If, when restarting the stove at the general switch at the rear of the
stove, the control panel display is not turned on, this means the service
fuse may need replacing.
There is a fuse box on the side of the stove, beneath the electricity
socket. Using a screwdriver, open the cover on the fuse box and
replace the fuses if necessary (3.15 A delayed).
8.3. Checking the internal components
CAUTION!
The internal electrical-mechanical components must
only be checked by qualified personnel with technical
expertise in combustion and electricity.
It is advisable to perform this routine annual maintenance (with a
scheduled service contract) focusing on the visual and functional check
of the internal components:
Below is a summary of the indispensable checks and/ or servicing tasks
for the stove to function correctly.
PARTS/ PERIOD
1 DAY
2-3 DAYS
30 DAYS
90 DAYS
1 YEAR
Brazier
●
Ash collection
t
t
●
Ash tray
●
Glass
●
Complete exchanger
●
Smoke duct
●
Door seal
●
Air filter
●
●
Remote control battery
(if purchased/