4.2. CHECK PRIOR TO START-UP
Check all the safety conditions covered previously.
Make sure you have read and fully understood the contents of this
instruction manual.
Remove all components which could burn from the combustion
chamber and glass (polystyrene, adhesive labels and instructions).
Check that the brazier is positioned correctly and rest it well on the
base.
Following long periods in which the stove is not used,
remove any remains of pellets from the tank (using a
vacuum cleaner with a long pipe). Pellet remains that
have been lying in the stove for some time may have
absorbed moisture, changing their original characteristics and
making them no longer suitable for combustion.
4.3. SETTINGS TO IMPLEMENT BEFORE THE FIRST
START-UP
Once the power supply cable at the rear of the stove is connected, turn
the switch (again at the rear) to position (I).
The illuminated button will light up and LED C on the emergency panel
will turn red (LIGHT PERMANENTLY ON)
4.4. LOADING PELLETS
The fuel is loaded via a flap on the side of the stove. Pour the pellets
into the tank. The empty tank holds approximately 18 Kg.
Do not put any type of fuel into the tank other than
pellets that comply with the specifications indicated
above.