beautypg.com

MCZ Philo User Manual

Page 27

background image

PELLET STOVES

Chapter 4

USE AND MAINTENANCE MANUAL

page

27

Operation

Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited

4.2. CHECK PRIOR TO START-UP

Check all the safety conditions covered previously.
Make sure you have read and fully understood the contents of this

instruction manual.
Remove all components which could burn from the combustion

chamber and glass (polystyrene, adhesive labels and instructions).
Check that the brazier is positioned correctly and rest it well on the

base.

Following long periods in which the stove is not used,

remove any remains of pellets from the tank (using a

vacuum cleaner with a long pipe). Pellet remains that

have been lying in the stove for some time may have

absorbed moisture, changing their original characteristics and

making them no longer suitable for combustion.

4.3. SETTINGS TO IMPLEMENT BEFORE THE FIRST

START-UP

Once the power supply cable at the rear of the stove is connected, turn

the switch (again at the rear) to position (I).
The illuminated button will light up and LED C on the emergency panel

will turn red (LIGHT PERMANENTLY ON)

4.4. LOADING PELLETS

The fuel is loaded via a flap on the side of the stove. Pour the pellets

into the tank. The empty tank holds approximately 18 Kg.

Do not put any type of fuel into the tank other than

pellets that comply with the specifications indicated

above.