10

Theoretical recommendations for installation

Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited

MCZ strongly recommends the use of certified fuel in

its stoves (DINplus and Ö-Norm M7135).
Using poor quality pellets or pellets that do not

comply with the indications given above

compromises the operation of your stove and may

consequently lead to decline of the guarantee and

liability for the product.

MCZ pellet stoves operate only with pellets of 5 mm

to max. 30 mm length and 6 mm diameter (in ITALY

only) or 6-8 mm diameter (in other European

countries).

2.2. INSTALLATION PRECAUTIONS

IMPORTANT!
The stove must be installed and assembled by

qualified staff.

The stove must be installed in a suitable place to allow normal opening

and regular maintenance.
The room in which the stove is installed must:

offer the correct environmental conditions for operation

be equipped with a 230V 50 Hz electrical power supply

offer a suitable smoke outlet system

be fitted with external ventilation

be fitted with an EC-compliant earthing system

The stove must be connected to a flue pipe or internal or

external vertical duct, in accordance with the applicable

standards in force.

The stove must be positioned so that the electrical plug is

accessible.

IMPORTANT!

The stove must be connected to a flue pipe or a

vertical duct that can discharge the smoke at the

highest point of the home.

The smoke does, however, result from combustion of

wood essences and may therefore soil walls if

released in contact with or close to them.

Caution: the smoke is not very visible but is very hot

and can cause burns on contact.

Before positioning the stove, holes must be made for

the smoke pipe passage and the external air inlet.

2.3. THE OPERATING ENVIRONMENT

For correct functioning and even distribution of heat, the stove should

be positioned in a location in which the air required for pellet

combustion can flow in (approximately 40 m

3

/h must be available), in

accordance with the installation regulations and applicable standards in

force in the country of installation.

The volume of the room should be no less than 30 m

3

.