PELLET STOVES

Chapter 3

USE AND MAINTENANCE MANUAL

page

22

Installation and assembly

Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited

The room ventilation can be adjusted towards the

rear wall only if there is suitable caulked ducting of

the hot air flow.

The air outlet pipe may reach very high temperatures

(nearing 200 °C). It must therefore be insulated

appropriately using suitable materials wherever it

may come into contact with flammable or heat-

sensitive surfaces (e.g. fading of colours, electrical

wireways, plasterboard, etc.). Persons and animals

must also be protected from voluntary or accidental

contact. In all cases observe the applicable

regulations and laws of the region in which the

appliance has been installed.

It is advisable to include insulation along the entire

route of the pipe to minimise dispersion and increase

heat output to the room.


When crossing through walls built with flammable materials, the FITTER

MUST suitably insulate the stove pipe crossing through it using suitable

insulating materials (thickness of 1.3-5 with min. heat conductivity of

0.07 W/m°K).
The pipe introduced into the wall must however be suitably insulated to

avoid losing heat and to soundproof the air outlet.

It is advisable to make ducts similar in length to

distribute the air in a uniform manner otherwise the

hot air will opt for the shortest or straightest

channel.

THROUGH WALL

INSULATOR

STOVE

HOT AIR OUTLET PIPE