Theoretical recommendations for installation
Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited
Always use pipes and connections with appropriate
seals that guarantee air- and watertightness.
All sections of the smoke duct must be accessible for
inspection and removable (us a T-union with inspection
point). This makes it possible to clean the inside of the stove
regularly.
Position the stove taking note of all the specifications and warnings
underlined so far.
IMPORTANT!
All 90° changes of direction in the smoke outlet
channel must be prepared with suitable T-unions
with inspection points (see pellet stove accessories).
It is absolutely forbidden to place a net at the end of
the outlet pipe as this may cause the stove to
malfunction.
WHEN CONNECTING THE FLUE PIPE NO MORE THAN
2 - 3 METRES OF HORIZONTAL PIPING SHOULD BE
USED AND NO MORE THAN THREE 90° BENDS
SHOULD BE USED
YOU ARE ALSO ADVISED NOT TO EXCEED A LENGTH
OF 6 METRES WITH A PIPE OF 80 mm DIAMETER
Example of pellet stove installation