Theoretical recommendations for installation

Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited

Always use pipes and connections with appropriate

seals that guarantee air- and watertightness.

All sections of the smoke duct must be accessible for

inspection and removable (us a T-union with inspection

point). This makes it possible to clean the inside of the stove

regularly.

Position the stove taking note of all the specifications and warnings

underlined so far.

IMPORTANT!
All 90° changes of direction in the smoke outlet

channel must be prepared with suitable T-unions

with inspection points (see pellet stove accessories).

It is absolutely forbidden to place a net at the end of

the outlet pipe as this may cause the stove to

malfunction.

WHEN CONNECTING THE FLUE PIPE NO MORE THAN

2 - 3 METRES OF HORIZONTAL PIPING SHOULD BE

USED AND NO MORE THAN THREE 90° BENDS

SHOULD BE USED
YOU ARE ALSO ADVISED NOT TO EXCEED A LENGTH

OF 6 METRES WITH A PIPE OF 80 mm DIAMETER


Example of pellet stove installation