background image

PELLET STOVES

Chapter 6

USE AND MAINTENANCE MANUAL

page

33

Emergency panel

Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited

6. EMERGENCY PANEL

The emergency panel is located on the side of the stove, at the bottom.

This panel is designed to diagnose any operating faults and is needed

to control the stove if the remote control is not working.

KEY

A. Three-figure display showing a series of information about the

stove as well as the ID code for possible operating faults.

B. GREEN LED that gives the following indications:

OFF = Stove off

FLASHING = Stove starting up

ON = Stove on

C. RED LED that gives the following indications:

OFF = Stove on

FLASHING SLOWLY = Stove switching off

FLASHING RAPIDLY = Stove in alarm status

(accompanied by an acoustic beep for the first 10

minutes)

ON = Stove off

D. Three-position selector for the function

OFF = Stove manually switched off with remote control

absent

REMOTE = Stove can only be controlled by the remote

control

ON = Stove manually switched on with remote control

absent

E. Three-position selector for power selection

MIN = Selector to operate the stove at MINIMUM power

with remote control absent and selector 4 set to ON

MED = Selector to operate the stove at MEDIUM power

with remote control absent and selector 4 set to ON

MAX = Selector to operate the stove at MAXIMUM power

with remote control absent and selector 4 set to ON

F. Button for diagnostic functions relating to the operation of the

stove

G. Button to enable communication between the stove and a new

remote control (via the process explained below)

TO ALLOW THE STOVE TO OPERATE WITH

THE REMOTE CONTROL, SELECTOR "D" MUST

BE SET TO "REMOTE"