6.1.1. Start-up/ shutdown via the emergency panel

If the remote control is faulty or the batteries are flat you can operate

the stove temporarily using the emergency panel on the rear of the

stove.

In this configuration, the stove can be operated manually and you can

choose between 3 power levels.

STARTING UP THE STOVE WITHOUT THE REMOTE

CONTROL

To start up the stove move selector “D” to the ON. When the

stove starts up the RED LED will switch off and the GREEN LED

will begin to flash until the start-up process is complete. The

GREEN LED stays on permanently while the stove is running.

SELECTING THE POWER LEVEL WITHOUT THE REMOTE

CONTROL

You can choose between three heating power levels:

MIN-MED-MAX (selector “E”)

MINIMUM power is the 1

st

power level;

MEDIUM power is the 3

rd

power level;

MAXIMUM power is the 5

th

power level;

SHUTTING DOWN THE STOVE WITHOUT THE REMOTE

CONTROL

To shut down the stove move selector “D” to the OFF

Once the remote control is working again remember

to put selector "D" back to the "REMOTE" position

otherwise the stove will ignore input from the

remote control.

6.1.2. Carica coclea (Load pellet)

This function, which can only be enabled when the stove is switched

off, is used to load pellets into the filling system (auger), and it can be

used every time the same is emptied because the pellets in the tank

have run out (see alarm A02). It is useful to avoid failed start-ups

(alarm A01) due in fact to an empty tank.
To enable the CARICA COCLEA (LOAD PELLET) function, when the

stove is switched off, set the selector “D” on the emergency panel to

OFF and press the TEST key on the same panel three times. Wait a

few seconds and the word COCLEA (AUGER) will flash on the screen.
When the pellets begin to drop into the brazier, press the TEST key

again to disable the CARICA COCLEA (LOAD PELLET) function and then

start up the stove.

D

E

ON

OFF

C A R

TEST

C O C

TEST