beautypg.com

C p1 – MCZ Philo User Manual

Page 30

background image

PELLET STOVES

Chapter 5

USE AND MAINTENANCE MANUAL

page

30

LCD remote control

Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited

12:07

31

°C

TU

23

°C

TIMER

ECO

12:06

31

°C

TU

23

°C

ECO

8:20

26

FR

20

°C

TIMER

°C

P1

5.5.3. TIMER mode (indicated by TIMER)

When you select this operating mode you can switch the product on

and off automatically according to 6 customisable time frames (P1 –

P6). In each time frame you can set:

 The start-up time

 The shut-down time

 The desired room temperature in that time frame

 The days of the week in which the time frame is active

When the stove is started up (manually using button A or automatically

using a time frame) the product operates in the automatic mode

described above. When a time frame is enabled it is automatically

displayed (P1 in figure 3) and the desired temperature modifies to the

value set in the time frame. The user can modify this value at any time,

in real time, as desired.
To learn how to set the time frames refer to paragraph 5.7.

5.5.4. ECO mode (indicated by ECO )

This mode enables/ disables when the remote control is switched on by

pressing button B for 5 seconds.
ECO mode is an automatic mode with the only difference that if the

temperature set is reached and maintained for the following 20 minutes

(regardless of the flame modulation) the product shuts down and

remains on stand-by until the room temperature drops 2 degrees below

the desired temperature (or until 5 minutes after the last shut down).

At this point the product restarts. Figure 4
If the room is not sufficiently insulated the flame modulation does not

allow the set temperature to remain satisfied for 20 consecutive

minutes and the product therefore does not shut down.

NOTE: We recommend that you use ECO mode only in well-

insulated rooms to prevent the appliance from starting up and

shutting down too frequently.

The remote control remains switched on, even while the product is

switched off due to ECO mode, to indicate that this shut down is only

temporary. Shutting down the product using button A exits ECO mode

and the product remains switched off.

In ECO mode you can also enable up to 6 automatic start-up/ shut

down time frames (E1 – E6). These are separate from those in the

TIMER mode (P1 – P6). If these time frames have been enabled the

message TIMER-ECO appears (figure 5) and is shown permanently

even when the remote control is switched off.
To learn how to set the time frames refer to paragraph 5.7.

NOTE: If the remote control shuts down by the TIMER, ECO

mode cannot restart until the user intervenes (button A) or the

next valid time frame is started. The use the TIMER combined

with ECO mode requires good knowledge of the operating logic

of the product.


FIG.5

FIG.4

FIG.3