Specifications

131

SCSI Interface

Interface type

SCSI 2 and SCSI 3

Logic level

TTL-compatible

ID setting

Selectable from 0 to 7

Terminator

Internal terminator (enable/disable
selectable)

Connector select switch

W: 68-pin

connector

N: 50-pin

connector

Connector type

Micro DB 50-pin connector
Micro DB 68-wide pin connector

Initialization methods

Hardware: Initialized when the scanner

is turned on or the scanner
receives a SCSI Reset signal
from the SCSI interface

Software:

Initialized when the
software sends the Esc @
(initialize the scanner
command), or the scanner
receives a SCSI Bus Device
message

IEEE 1394 Scanner Interface

Interface type

IEEE 1394 compatible

Data transfer method

Half-duplex Data/Strobe differential
serial

Synchronization method

Clock synchronization with DS-Link

Encoding/decoding

DS-Link

Logic level

3.3 V

Compatible connectors

IEEE 1394-1995 compatible

Power class

Power class code 100
No power supply from external sources
Fitted with a repeat function with bus
power

Environmental

Temperature

Operating: 41 to 95 °F

(5 to 35 °C)

Standby:

13 to 140 °F

(

25 to 60 °C)

Humidity (without condensation)

Operating: 10 to 80%
Standby:

10 to 85%

Option Interface Connector

Interface type

For use with the automatic document
feeder (B813212)

Output voltage

21.6 to 26.4 VDC
4.75 to 5.25 VDC

Output current

0.6 A (24 V)
0.3 A (5 V)