Store capacitance 2000

Enclosure

Double molded, waterproof

Shock (Drop Test)

6.5 feet (2 meters)

Diode Test

Test current of 0.9mA maximum, open

circuit voltage 2.8V DC typical

Continuity Check

Audible signal will sound if the resistance is

less than 35

Ω (approx.), test current

<0.35mA

Peak

Captures peaks >1ms

Temperature Sensor

Requires type K thermocouple

Input Impedance

>10MΩ VDC & >9MΩ VAC

AC Response

True rms

AC True RMS: The term stands for “Root-Mean-Square,”

which represents the method of calculation
of the voltage or current value. Average
responding multimeters are calibrated to
read correctly only on sine waves and they
will read inaccurately on non-sine wave or
distorted signals. True rms meters read
accurately on either type of signal.

ACV Bandwidth

50Hz to 1000Hz

Crest Factor

≤3 at full scale up to 500V, decreasing

linearly to ≤1.5 at 1000V

Display

40,000 count backlit liquid crystal with

bargraph

Overrange indication

OL” is displayed

Auto Power Off

15 minutes (approximately) with disable

feature

Polarity

Automatic (no indication for positive); Minus
(-) sign for negative

Measurement Rate

2 times per second, nominal

Low Battery Indication “ ” is displayed if battery voltage drops

below operating voltage