CAPACITANCE MEASUREMENTS
WARNING: To avoid electric shock, disconnect power to the unit
under test and discharge all capacitors before taking any
capacitance measurements. Remove the batteries and unplug the
line cords.
1. Set the rotary function switch to the green
Ω CAP position.
2. Insert the black test lead banana plug into
the negative COM jack.
3. Insert the red test lead banana plug into
the positive V jack.
4. Press the MODE button to indicate “F”
5. Touch the test leads to the capacitor to be
tested.
Read the capacitance value in the
Display
TEMPERATURE MEASUREMENTS
1. Set the function switch to the green
Temp position.
2. Insert the Temperature Probe into the
input jacks, making sure to observe the
correct polarity.
3. Press the MODE button to indicate “ºF”
or “ºC”
4. Touch the Temperature Probe head to
the part whose temperature you wish to
measure. Keep the probe touching the
part under test until the reading
stabilizes (about 30 seconds).
5. Read the temperature in the display.
Note: The temperature probe is fitted with a type K mini connector.
A mini connector to banana connector adaptor is supplied for
connection to the input banana jacks.