Sealey TA202 User Manual
Ta202, Digital automotive analyser 14 function with ic, Instructions for
. . . . . . . . . . . . . . . . . . . . . Continuity
BAT . . . . . . . . . . . . . . . . . Low Battery
. . . . . . . . . . . . . . . . . . . . . Diode
DATA HOLD . . . . . . . . . . . Data Hold
Auto . . . . . . . . . . . . . . . . . Auto Ranging
AC . . . . . . . . . . . . . . . . . . Alternating Current
DC . . . . . . . . . . . . . . . . . . Direct Current or Voltage
1.1.
PERSONAL PRECAUTIONS
When using this meter, please observe all normal safety rules concerning:
Protection against the dangers of electric current .
Protection of the meter against misuse .
Full compliance with safety standards can only be guaranteed if used with the test leads supplied . If necessary, they must be replaced with genuine Sealey
leads with the same electronic ratings . Failure to do so will invalidate the warranty .
DO NOT use leads if damaged or if the wire is bared in any way .
1.2.
GENERAL SAFETY INSTRUCTIONS
Familiarise yourself with the applications, limitations and hazards of the meter .
IF IN ANY DOUBT CONSULT A QUALIFIED ELECTRICIAN.
When the meter is linked to a measurement circuit, do not touch unused meter terminals .
When the scale of the value to be measured is unknowen set the selector to the highest range available .
Before rotating the range selector to change functions, disconnect test leads from the circuit under test .
WARNING! Never perform resistance measurements on live circuits.
Always be careful when working with voltages above 60Vdc or 30Vac rms . Keep your fingers behind the probe guards while measuring .
When not in use, store the meter carefully in a safe, dry, childproof location . Storage temperature range -10
°C to 50°C .
Never apply voltage or current to the meter that exceeds the specified maximum .
The user shall ensure that test probes are correctly selected in order to prevent danger . Probes shall be selected to ensure that adequate barriers guard against
inadvertent hand contact with live conductors under test and that probes have minimal exposed probe tips . Where there is a risk of the probe tip short circuiting
with other live conductors under test, it is recommended that the exposed tip length shall not exceed 4mm .
Layout: (Refer to fig . 1 .)
1 . Large LCD display
2 . Rotary switch
3 . COM, negative input jack
4 . Positive (+) input for AC/DC Voltage, Current, Hz, %duty, Cycle, Ohms, Diode, Continuity,
Capacitance, Temperature (°C or °F), RPM, Dwell and Pulse Width .
5 . Positive (+) input jack for AC/DC µA/mA .
6 . Positive (+) 20A input jack for 20A AC/DC measurements .
7 . Data Hold and backlight push button .
8 . Relative push button .
9 . RPM, DWELL, Hz%, CYL, mS ± button .
10 . Mode push button .
INSTRUCTIONS FOR:
DIGITAL AUTOMOTIVE ANALYSER 14 FUNCTION
WITH IC
MODEL No:
TA202
1. SAFETY
Input Limits
Function
Maximum Input
V AC or V DC
700V AC, 1000V DC
mA AC/DC
400mA AC/DC
A AC/DC
20A AC/DC (30 secs
max every 15 minutes)
Frequency
Resistance
Duty Cycle
Diode Test
Continuity
Temperature
RPM
DWELL
Pulse Width
250V AC/DC
Extra large, hi-contrast LCD display with 36mm high digital read-out and backlight . Durable bi-composite case and integral stand suitable for the toughest
workshop conditions . Features millisecond pulse-width function for accurate measurement of fuel injection systems . Includes auto-ranging, data hold and
auto-power off . Supplied with tough nylon carry case and shoulder strap, inductive coupler, for fast reading of engine rpm, test probes and thermocouple .
Symbols & Description
Fig. 1.
Inductive Pickup
Test Probes
Termocouple
TA202 Issue No: 3(L) - 17/06/14
Original Language Version
© Jack Sealey Limited
2. FEATURES
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE
PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.