beautypg.com

Meg ohms – Sealey TA320 User Manual

Page 34

background image

Meg OHMS

Terminal

Voltage

Range

Resolution

Accuracy

Test

Current

Short

circuit

current

125V(0

%~+10

%)

0.125~4.000 M

Ω

0.001M

Ω

+(2%+10)

1mA

@load1

25k

Ω

1mA

4.001~40.00 M

Ω

0.01M

Ω

+(2%+10)

40.01~400.0 M

Ω

0.1M

Ω

+(4%+5)

400.1~4000 M

Ω

1M

Ω

+(5%+5)

250V

(0%~+1

0%)

0.250~4.000 M

Ω

0.001M

Ω

+(2%+10)

1mA

@load2

50k

Ω

1mA

4.001~40.00 M

Ω

0.01M

Ω

+(2%+10)

40.01~400.0 M

Ω

0.1M

Ω

+(3%+5)

400.1~4000 M

Ω

1M

Ω

+(4%+5)

500V(0

%~+10

%)

0.500~4.000 M

Ω

0.001M

Ω

+(2%+10)

1mA

@load5

00k

Ω

1mA

4.001~40.00 M

Ω

0.01M

Ω

+(2%+10)

40.01~400.0 M

Ω

0.1M

Ω

+(2%+5)

400.1~4000 M

Ω

1M

Ω

+(4%+5)

1000V

(0%~+1

0%)

1.000~4.000 M

Ω

0.001M

Ω

+(3%+10)

1mA

@load1

M

Ω

1mA

4.001~40.00 M

Ω

0.01M

Ω

+(2%+10)

40.01~400.0 M

Ω

0.1M

Ω

+(2%+5)

400.1~4000 M

Ω

1M

Ω

+(4%+5)



Note:
Accuracy specifications consist of two elements:
• (% reading) – This is the accuracy of the measurement circuit.

• (+ digits) – This is the accuracy of the analog to digital converter.