Specifications

Function

Range

Resolution

Accuracy

DC Voltage

400mV

0.01mV

± (0.06% reading + 4digits)

4V

0.0001V

40V

0.001V

400V

0.01V

1000V

0.1V

± (0.1% reading + 5digits)

AC Voltage

50 to 1000Hz

400mV

0.1mV

± (1.0% reading + 7digits)

4V

0.001V

40V

0.01V

± (1.0% reading + 5 digits)

400V

0.1V

1000V

1V

AC+DCVoltage

400mV

0.1mV

± (1.0% reading + 7digits)

(50/60HZ)

4V

0.001V

40V

0.01V

400V

0.1V

1000V

1V

All AC voltage ranges are specified from 5% of range to
100% of range

DC Current

400

µA

0.01

µA

± (1.0% reading + 3 digits)

4000

µA

0.1

µA

40mA

0.001mA

400mA

0.01mA

10A

0.001A