Sealey MM405 User Manual
Model no:mm405, Mini ac/dc clamp meter
INSTRUCTIONS FOR:
MINI AC/DC CLAMP METER
MODEL No:MM405
1.1.
PERSONAL PRECAUTIONS
3 When using this meter, please observe all normal safety rules concerning:
Protection against the dangers of electric current.
Protection of the meter against misuse.
1.2. GENERAL SAFETY INSTRUCTIONS
3 Familiarise yourself with the applications, limitations and hazards of the meter. IF IN DOUBT CONSULT A
QUALIFIED ELECTRICIAN.
3 Always be careful when working with voltages above 35Vdc or 25Vac rms. These voltages are considered a
shock hazard.
3 When not in use, store the meter carefully in a safe, dry, childproof location. Storage temperature range -30
O
C to
6 0
O
C.
3 Never apply voltage or current to the meter that exceeds the specified maximum.
Layout: ( Refer to fig. 1. )
1.
Current clamp.
2.
Flash light button.
3.
Rotary function switch.
4.
Data hold and backlight button.
5.
LCD display.
6.
Clamp trigger.
7.
Zero button.
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instruc-
tions and properly maintained, give you years of trouble free performance.
1.
SAFETY INSTRUCTIONS
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS,
WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS
INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE
WARRANTY. PLEASE KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
2.
FEATURES
Input Limits
Function
Maximum Input
AC Current
200A
DC Current
± 200A
Frequency
1kHz
Durable composite housing with rubber grip around handle for comfort
and control. Designed to verify the presence of AC and DC current and
with non-contact voltage detection, with flashlight and non-contact
frequency measurement. Perfect for the automotive electrician.
Features a backlit LCD display and an LED light at the front of the unit
for working in dark areas. Comes complete with carry case.
1
2
6
3
4
7
5
Fig.1
Fig.2
Display:
(Refer to fig. 2.)
AC DC
AC (alternating current) and DC (direct current)
Minus sign.
2400 count (0 to 2400) measurement reading
AUTO
AutoRange mode.
HOLD
Data Hold mode.
BAT
Low Battery icon.
Hz%
Frequency measurement.
MM405 - 1 - 260505