Name

Description

Multi-Function

Photocoupler 2

Terminal P2

0: Terminal P2 OFF

1: Terminal P2 ON

Output Frequency

Actual Drive Speed

Monitors drive output frequency.

Unit depends on o1-03.

Unit is not affected by Speed Scale SS.

Torque Actual

Output Torque, not supported

Current Actual

Actual Output Current

Monitors drive output current.

Unit is 0.01 A.

Unit is not affected by Current Scale CS.

u

Extended Speed/Torque Status Input (Vendor Specific Yaskawa Electric (YE) Assy) -
155 (0x9B)

Output Instance

Word

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

155

0

0

Faulted

Alarm

Ready

Speed

Agree

Fault Reset

REV

Running

ZSP

Running

1

Multi-

Function

Photo-

coupler 2

Multi-

Function

Photo-

coupler 1

Multi-

Function

Digital

Output

LOCAL/

REMOTE

Uv

oPE

1

2

Motor Speed (Low Byte)

3

Motor Speed (High Byte)

2

4

Torque Actual (Low Byte), not supported

5

Torque Actual (High Byte), not supported

3

6

PG Count Value (Low Byte)

7

PG Count Value (High Byte)

4

8

Frequency Command (Low Byte)

9

Frequency Command (High Byte)

5

10

Output Frequency (Low Byte)

11

Output Frequency (High Byte)

6

12

Output Current (Low Byte)

13

Output Current (High Byte)

7

14

Parameter F7-35

Default: Terminal A2 Input (Low Byte)

15

Parameter F7-35

Default: Terminal A2 Input (High Byte)

8

16

Main Circuit DC Voltage (Low Byte)

17

Main Circuit DC Voltage (High Byte)

9

18

Error Code (Low Byte)

19

Error Code (High Byte)

9 Input Assemblies (Drive Produces)

YASKAWA SIEP YAICOM 15A V1000 Option Dual-Port EtherNet/IP SI-EN3D/V Technical Manual