Yaskawa V1000 Option Dual Port EtherNet/IP SI-EN3D/V Technical Manual User Manual
Page 35

Name
Description
Multi-Function
Photocoupler 2
Terminal P2
0: Terminal P2 OFF
1: Terminal P2 ON
Output Frequency
Actual Drive Speed
Monitors drive output frequency.
Unit depends on o1-03.
Unit is not affected by Speed Scale SS.
Torque Actual
Output Torque, not supported
Current Actual
Actual Output Current
Monitors drive output current.
Unit is 0.01 A.
Unit is not affected by Current Scale CS.
u
Extended Speed/Torque Status Input (Vendor Specific Yaskawa Electric (YE) Assy) -
155 (0x9B)
Output Instance
Word
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
155
0
0
Faulted
Alarm
Ready
Speed
Agree
Fault Reset
REV
Running
ZSP
Running
1
–
–
Multi-
Function
Photo-
coupler 2
Multi-
Function
Photo-
coupler 1
Multi-
Function
Digital
Output
LOCAL/
REMOTE
Uv
oPE
1
2
Motor Speed (Low Byte)
3
Motor Speed (High Byte)
2
4
Torque Actual (Low Byte), not supported
5
Torque Actual (High Byte), not supported
3
6
PG Count Value (Low Byte)
7
PG Count Value (High Byte)
4
8
Frequency Command (Low Byte)
9
Frequency Command (High Byte)
5
10
Output Frequency (Low Byte)
11
Output Frequency (High Byte)
6
12
Output Current (Low Byte)
13
Output Current (High Byte)
7
14
Parameter F7-35
Default: Terminal A2 Input (Low Byte)
15
Parameter F7-35
Default: Terminal A2 Input (High Byte)
8
16
Main Circuit DC Voltage (Low Byte)
17
Main Circuit DC Voltage (High Byte)
9
18
Error Code (Low Byte)
19
Error Code (High Byte)
9 Input Assemblies (Drive Produces)