<6> When F7-14 is set to 0 or 2, parameter F7-15 must be set.
<7> Default setting differs depending on drive software version. PRG: 1012 to 1015: 0
PRG: 1016 and later: 1
<8> Setting range differs depending on drive software version. PRG: 1012 to 1023, Range: 0 to 2
PRG: 1024 and later, Range: 0 to 8
<9> Setting values differ depending on drive software version. PRG: 1012 to 1015, Default: 0; Range: 0, 10, 100
PRG: 1016 to 1023, Default: 10; Range: 10, 100
PRG: 1024 and later, Default: 10; Range: 10; 100 to 102
Table 8 Option Monitors
No.
Name
Description
Value Range
U6-80 to
U6-83
Online IP Address
IP Address currently available; U6-80 is the most significant octet
0 to 255
U6-84 to
U6-87
Online Subnet
Subnet currently available; U6-84 is the most significant octet
0 to 255
U6-88 to
U6-91
Online Gateway
Gateway currently available; U6-88 is the most significant octet
0 to 255
U6-92
Online Speed
Link Speed
10: 10 Mbps
100: 100 Mbps
U6-93
Online Duplex
Duplex Setting
0: Half, 1: Full
U6-94
Port 2 Duplex
Port 2 Duplex Setting
0: Half, 1: Full
U6-95
Port 2 Speed
Port 2 Link Speed
10: 10 Mbps
100: 100 Mbps
U6-98
First Fault
First Option Fault
–
U6-99
Current Fault
Current Option Fault
–
6 Related Drive Parameters
22