5.4 Installation Conditions

Table 5.6 Installation conditions

Parameter

Specification

Operating temperature range

-25°C to 60°C (possible power reduction above 45°C)
(-13°F to 140°F) (possible power reduction above 113°F)

Storage temperature

-40°C to 60°C

Relative humidity

95% (non-condensing)

Pollution degree

PD2

Environmental category IEC62109-1

Outdoor, wet (see Section 2, page 21)

Environmental class in accordance with IEC 60721-3-4

4K4H/4Z4/4B2/4S3/4M2/4C2

Cooling concept

Forced cooling

Air quality - general

ISA S71.04-1985
Level G3 (at 75% RH)

Air quality - coastal, heavy industrial and agricultural zones Must be measured and classified in accordance with ISA

S71.04-1985: G3 (at 75% RH)

Vibration

< 1 G

Enclosure protection class

IP65

UL 50E enclosure type

NEMA 3R

Maximum operating altitude above mean sea level

2,000 m (6,500 ft) above sea level (derating may occur at
an altitude over 1,000 m).*

Installation

Avoid constant stream of water.
Avoid direct solar irradiation.
Ensure adequate air flow.
Mount on non-flammable surface.
Mount upright on vertical surface.
Prevent dust and ammonia gases.

* Installations at heights >2,000 are possible on request. Contact SMA Solar Technology AG.