4 Service
SMA Solar Technology AG
42
STP60-10-IA-xx-10
Installation Guide
Table 4.3 System-related events
Internal events
2054
Transmitting the grid code from
SMA Inverter Manager to
STP 60-10 failed.
If the occurs repeatedly, contact
the Service.
-
-
-
ID
Status
message
Description
Measure
DGO
Hotline PV
ID
Status
message
Description
Measure
DGO
Hotline PV
201 to
208
The internal temperature of the
inverter is too high.
Make sure that there are no
objects or dust on the inverter and
that the air duct is not blocked.
-
-
-
209,
210
Voltage in DC link is too high. If the event persists, reset the
inverter by disconnecting DC and
AC. If the event is repeated, check
the maximum PV voltage using the
display to see if it is above the
limits.
-
-
-
211
Low fan
speed
Fan speed is too low.
Check whether the inverter fan is
blocked.
-
-
-
213 to
215
Internal error. Voltage
measured before and after the
relay differs too much.
Contact the Service.
-
-
-
216 to
218
Current measured on AC side
is too high.
Contact the Service.
-
-
-
219 to
221
Internal error. Voltage
measured before and after the
relay differs too much.
Contact the Service.
-
-
-
225 to
240,
275
Failure in memory/EEPROM.
Restart the inverter. If the event
persists, call the Service.
-
-
-
241,
242,
245,
249
Internal communications fault. Restart the inverter. If the event
persists, call the Service.
-
-
-
248
Internal CPU error.
Restart the inverter. If the event
persists, call the Service.
-
-
-
252 to
254
Current measured on AC side
is too high.
If the event repeats, call Service.
-
-
-
243,
263
Internal error.
Restart the inverter. If the event
persists, call the Service.
-
-
-
279
Temperature sensor error.
If the event persists, call the
Service.
-
-
-