beautypg.com

4 pr ogr am run – HEIDENHAIN iTNC 530 (606 42x-02) ISO programming User Manual

Page 553

background image

HEIDENHAIN iTNC 530

553

16.4 Pr

ogr

am Run

U

To go to the first block of the current program to start a block scan,
enter GOTO “0”.

U

To select block scan, press the BLOCK SCAN soft key,

or

U

Start-up at N:

Enter the block number N at which the

block scan should end

U

Program:

Enter the name of the program containing

block N

U

Start-up at P

: Enter the number P at which the block

scan should end if you want to start in a point table

U

Table (PNT)

: Enter the name of the point table in

which the block scan should end

U

Repetitions:

If block N is located in a program section

repeat or in a subprogram that is to be run repeatedly,
enter the number of repetitions to be calculated in the
block scan

U

To start the block scan, press the machine START

button

U

Contour approach (see following section)

Entering a program with the GOTO key

Danger of collision!

If you use the GOTO block number key for going into a
program, neither the TNC nor the PLC will execute any
functions that ensure a safe start.

If you use the GOTO block number key for going into a
subprogram, the TNC will skip the end of the subprogram
(G98 L0)! In such cases you must always use the
mid-program startup function.