beautypg.com

3 fixt ur e monit o ri ng (dcm sof tw a re option) – HEIDENHAIN iTNC 530 (606 42x-02) ISO programming User Manual

Page 362

background image

362

Programming: Special Functions

1

1

.3 Fixt

ur

e Monit

o

ri

ng (DCM

Sof

tw

a

re

Option)

U

Set-up clearance

:

Setup clearance to the measuring point that the TNC
should maintain during pre-positioning. Input range 0
to 99999.9999

U

Tolerance

:

Maximum permissible deviation between nominal
and actual position of the respective test points. Input
range 0 to 99999.999. If the test point is out of
tolerance, the TNC issues an error message

U

Tool number/tool name

:

Tool number (or name) of the touch probe. Input
range 0 to 30000.9 if a number is entered; maximum
16 characters if a name is entered. If entering a tool
name, enter it between single quotation marks

U

Confirm the entries: The TNC generates the test

program, shows the name of the test program in a
pop-up window and asks whether you want to run the
test program

U

Answer with NO if you want to run the test program

later, and with YES if you want to run it now

U

If you have confirmed with YES, the TNC changes to

the Full Sequence mode and automatically selects
the generated program

U

Start the test program: The TNC prompts you to

manually pre-position the touch probe so that it is
located at clearance height. Follow the instructions in
the pop-up window

U

Start the measuring process: The TNC moves to each

test point one after the other. With a soft key you
specify the positioning strategy. Conform with NC
start each time

U

At the end of the test program the TNC displays a pop-

up window with the deviations from the nominal
position. If a test point is out of tolerance, the TNC
issues an error message in the pop-up window