D15 print: output of texts or q parameter values, 7 a d ditional f unctions – HEIDENHAIN iTNC 530 (606 42x-02) ISO programming User Manual
Page 291
HEIDENHAIN iTNC 530
291
9.7 A
d
ditional F
unctions
D15 PRINT: Output of texts or Q parameter
values
The function D15 transfers Q parameter values and error messages
through the data interface, for example to a printer. When you save
the data in the TNC memory or transfer them to a PC, the TNC stores
the data in the file %FN 15RUN.A (output in program run mode) or in
the file %FN15SIM.A (output in test run mode).
The data are transmitted from a buffer. Data output begins at the latest
by program end or when you stop the program. In the Single Block
mode of operation, data transfer begins at block end.
To output dialog texts and error messages with FN 15: PRINT
“numerical value”
Example: Output of dialog text 20
Outputting dialog texts and Q parameters with D15 PRINT
“Q parameter”
Application example: Recording workpiece measurement.
You can transfer up to six Q parameters and numerical values
simultaneously. The TNC separates them with slashes.
Example: Output of dialog text 1 and numerical value for Q1
1100
Kinematic access not possible
1101
Meas. pos. not in traverse range
1102
Preset compensation not possible
Error number
Text
Setting the data interface: In the menu option PRINT or
PRINT-TEST, you must enter the path for storing the texts
or Q parameters. See “Assignment” on page 566.
Numerical values from 0 to 99:
Dialog texts for OEM cycles
Numerical values 100 and above: PLC error messages
N67 D15 P01 20 *
N70 D15 P01 1 P02 Q1 *