beautypg.com

Grass Valley KAM-XM-SERIES v.1.4.1 User Manual

Page 66

background image

66

KAM-XM-SERIES Instruction Manual

Configuration and Adjustments

When the

Restore upon Install

box has been checked, the current configu-

ration saved to this slot is saved as slot memory. When the current
module is removed and another module of the same type and software
version is installed, the configuration saved to the 2000NET module
will be downloaded to the new module. The box must be checked
before the current module with the saved configuration is removed.

If a different type of module is installed in this slot, a warning message
will state that the original module type has been replaced with another
module type. In this case, a

Clear

button will appear allowing you to

clear the stored configuration from the previous module.

Note

Uncheck the Restore Upon Install button before downloading new software.

Frame Health Reports Link

– will appear only on a module installed in a

2000T3 (3 RU) frame. Select the Frame Health Reports link to open the
2000NET module Frame Alarm Reporting web page. This web page
allows configuration of what alarms and warnings are reported to the
external Frame Health Alarm connector on the rear of the frame.

Note

This page is only present on the 2000T3 frame. The 2000T1 frame does not
have an external Frame Health alarm.

This web page contains the following sections:

Hardware Switch Status

– the Hardware Switch Status section of this

web page displays the current settings of the alarm and warning
configuration DIP switches, S1 and S2, on the 2000NET circuit
board in this frame. These switches allow enabling and disabling of
what overall status reporting information is provided to the
external Frame Alarm.

Output Format for Warnings

– set the Output Format for Warnings on the

external RS-232 Frame Alarm output on the rear of the frame. When
the

Open

radio button is selected, warnings are not reported to the

external frame alarm. Selecting the

Closed

radio button, causes

warnings to be reported in the same manner as alarms.

Frame Health Reporting

– this section provides a table showing the

presence and status of all frame devices such as modules, power
supplies, and fans and other frame functions such as Module
Health and Frame Bus status. Use the corresponding

Report

check-

boxes to indicate which alarms and warnings should be reported to
the Frame Health alarm for the following conditions:

Faults

Signal Loss

Reference Loss

Config Error