5. Repeat the process for the second Fibre Channel Controller as follows:
a) Right-click on the remaining Fibre Channel Controller and select
Update Driver…
b) On the Welcome page, select
No, not this time
and then click
Next
.
c) Select
Install from a list or specific location
and then click
Next
.
d) Browse to
C:\Profile\Drivers\ Atto 8Gb HBA Drivers
and select the
x86
directory if
installing on a 32-bit computer or the
x64
directory if installing on a 64-bit computer..
e) Click
OK
.
f) Click
Next
.
g) Click
Finish
when prompted.
6. Verify that the two "ATTO" devices are now listed under the SCSI and RAID Controllers
7. Close the Device Manager and System windows
Next, do final steps.
Final steps for software and CPU carrier module upgrades
Do this task for both software and CPU carrier module upgrade kits.
1. If you have not already done so, manage the Embedded Security. Make sure Update mode is
ended.
2. Check the Windows operating system clock and, if necessary, set it to the correct time.
3. If you installed K2-XDP2-V9-FK, apply the Windows operating system sticker that you received
with the upgrade kit. Attach it to the K2 Summit/Solo system, in the same location as the previous
Windows operating system sticker.
4. If you are upgrading a K2 Summit SAN-attached system, on the K2 SAN’s control point PC,
use the K2Config application to add the K2 Summit system back to the SAN.
5. When the K2 Summit/Solo system is fully configured, licensed, and operational, create a
first-birthday disk image and store it on the USB Recovery Flash Drive. Refer to the K2 product's
Service Manual for procedures.
6. Disconnect the USB Recovery Flash Drive and store it in the front bezel assembly.
If present, discard the previous USB Recovery Flash Drive.
The upgrade process is complete for the following upgrade kits:
•
K2-XDP2-CPU-FK
•
K2-XDP2-V9-FK
For a K2 Summit system upgraded with the K2-XDP2-CPU-FK kit, if you do any service work or
replace any Field Replaceable Units (FRUs), first consult "K2 Summit 3G Production Client Service
Manual". This is true even if replacing an original FRU that has not been upgraded. System
dependencies involving FRUs require procedures found only in "K2 Summit 3G Production Client
Service Manual".