5. Repeat the process for the second Fibre Channel Controller as follows:

a) Right-click on the remaining Fibre Channel Controller and select

Update Driver…

b) On the Welcome page, select

No, not this time

and then click

Next

.

c) Select

Install from a list or specific location

and then click

Next

.

d) Browse to

C:\Profile\Drivers\ Atto 8Gb HBA Drivers

and select the

x86

directory if

installing on a 32-bit computer or the

x64

directory if installing on a 64-bit computer..

e) Click

OK

.

f) Click

Next

.

g) Click

Finish

when prompted.

6. Verify that the two "ATTO" devices are now listed under the SCSI and RAID Controllers

7. Close the Device Manager and System windows

Next, do final steps.

Final steps for software and CPU carrier module upgrades

Do this task for both software and CPU carrier module upgrade kits.

1. If you have not already done so, manage the Embedded Security. Make sure Update mode is

ended.

2. Check the Windows operating system clock and, if necessary, set it to the correct time.

3. If you installed K2-XDP2-V9-FK, apply the Windows operating system sticker that you received

with the upgrade kit. Attach it to the K2 Summit/Solo system, in the same location as the previous
Windows operating system sticker.

4. If you are upgrading a K2 Summit SAN-attached system, on the K2 SAN’s control point PC,

use the K2Config application to add the K2 Summit system back to the SAN.

5. When the K2 Summit/Solo system is fully configured, licensed, and operational, create a

first-birthday disk image and store it on the USB Recovery Flash Drive. Refer to the K2 product's
Service Manual for procedures.

6. Disconnect the USB Recovery Flash Drive and store it in the front bezel assembly.

If present, discard the previous USB Recovery Flash Drive.

The upgrade process is complete for the following upgrade kits:

K2-XDP2-CPU-FK

K2-XDP2-V9-FK

For a K2 Summit system upgraded with the K2-XDP2-CPU-FK kit, if you do any service work or
replace any Field Replaceable Units (FRUs), first consult "K2 Summit 3G Production Client Service
Manual". This is true even if replacing an original FRU that has not been upgraded. System
dependencies involving FRUs require procedures found only in "K2 Summit 3G Production Client
Service Manual".

Related Topics

Manage Embedded Security Update mode

on page 47

26

K2 Summit/Solo/Media Server Field Kit Upgrade Instructions

20140204