3. In Network and Sharing Center, select
Change adapter settings
.
Network Connections opens and displays network adapters, including the following:
•
Control Connection #1
•
Control Connection #2
•
Media Connection #1
•
Media Connection #2
4. For each Control Connection and each Media Connection, do the following:
a) Right-click the connection and select
Properties
.
The Connection Properties dialog box opens.
b) In the Connection Properties dialog box, click
Configure
.
The Adapter Properties dialog box opens.
c) In the Adapter Properties dialog box, click the
Advanced
tab.
d) On the Advanced tab, in the Settings list select
Large Send Offload v2 (IPv4)
and then in the
Value drop-down list select
Disabled
.
e) Click
OK
to save settings and close.
f) Repeat these steps for each Control Connection and each Media Connection.
Next, disable CPU power technology.
Disable CPU Power Technology
1. Restart the K2 Summit/Solo system.
2. During the BIOS startup screen, press
F2
repeatedly until
Entering Setup...
appears.
The BIOS screen opens.
3. On the BIOS screen, use arrow keys and select the
Advanced
tab.
4. On the Advanced tab select
CPU Core Configuration
and then press
Enter
.
The CPU Core Configuration screen opens.
5. On the CPU Core Configuration screen, select
Power Technology
and then press
Enter
.
A Power Technology dialog box opens.
6. In the Power Technology dialog box select
Disable
and then press
Enter
.
7. Press
F4
to save and exit.
A Save & Exit Setup dialog box opens.
8. In the Save & Exit Setup dialog box, select
Yes
and then press
Enter
.
9. The K2 Summit/Solo system restarts.
Next, install the SiteConfig Discovery Agent.
20140204
K2 Summit/Solo/Media Server Field Kit Upgrade Instructions
17
Installing software and CPU carrier module upgrades