5. If the K2 Summit system has a dual port Fibre Channel card, on the Found New Hardware wizard,

install the driver on the second LSI Pseudo Device port as follows:

a) Select

Install from a list or specific location

and then click

Next

.

b) Select

Don’t search. I will choose the driver to install

and then click

Next

.

c) Select

Have Disk

.

d) Browse to

C:\Windows

and find LSI_SCSIPORT_1.21.25.00. Click

Open

and

OK

.

e) Start the driver install by selecting

Next

.

f) On the Hardware Installation page, click

Continue Anyway

.

g) Click

Finish

.

6. If the K2 Summit system is on a redundant K2 SAN or is connected to direct-connect storage,

make the following registry settings:

[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\Symmpi\Parameters\Device]

"DriverParameter"="MPIOMode=2"

"MaximumSGList"=dword:000000ff

"NumberOfRequests"=dword:00000020

Next, do final steps.

Install the ATTO Fibre Channel card driver

1. Open Device Manager.

2. Right-click on

K2 Summit Client

and select

Manage.

3. Click

Device Manager

4. Install the first Fibre Channel driver as follows:

a) Right click on the upper Fibre Channel Controller and select

Update Driver…

b) On the Welcome page, select

No, not this time

and then click

Next

.

c) Select

Install from a list or specific location

and then click

Next

.

d) Browse to

C:\Profile\Drivers\ Atto 8Gb HBA Drivers\x86

.

e) Click

OK

.

f) Click

Next

.

g) Click

Finish

when prompted.

h) In the Found new hardware wizard that will open for the ATTO Phantom device, select

No,

not this time

.

i) Select

Install from a list or specific location

and then click

Next

.

j) Browse to

C:\Profile\Drivers\ Atto 8Gb HBA Drivers

and select the

x86

directory if

installing on a 32-bit computer or the

x64

directory if installing on a 64-bit computer.

k) Click

OK

.

l) Click

Next.

.

m) Click

Finish

when prompted.

20140204

K2 Summit/Solo/Media Server Field Kit Upgrade Instructions

25