Jupiter AccuSwitch Soft Panels and Visual Status Display Instruction Manual

13

Jupiter File Server Settings

Jupiter File Server Settings

The following overview assumes that the reader is familiar with the Jupiter
Facility Control System. If not, please refer to the Jupiter CM-4000 Installa-
tion and Operating
manual.

MPK Table Entries

Although the Soft Panel and VSD applications are not actually an MPK-
type panel (it does not use the Message Per Keystroke protocol), the MPK
table is used for configuration purposes.

MPK Device

- This column is used to create a name, up to eight characters in

length, for each Soft Panel. This name must be unique system-wide.

Type

- Select type

CP-ESLAN

on the pull-down menu. Select

“CPESXTND” for use with 98 categories.

Expansion

- Not used for Soft Panels (leave unchecked).

Password

- Not used for Soft Panels.

Board

- Name of AccuSwitch Controller associated with this Soft Panel. The

source of this name is the Network Description table.

Port

- Not used for Soft Panels.

Address

- Panel address from 01 to 64. Must be unique for panels associated

with the same AccuSwitch Controller. This number is referred to as the
“Device ID” on the Soft Panel “Devices > Settings” menu.

Input Set

- Name of CP Input Set to be assigned to this panel. The usual prac-

tice is to have one CP Input Set, containing the names of all sources, be
applied to all panels. However, special CP Input Sets could be created
which list only selected sources. Such a set could be used to prevent certain
panels from selecting specific sources.

In Panel

- This column is not used for Soft Panels.

Out Set

- Name of the CP Output Set to be assigned to this panel. If the entry

is an actual CP Output Set, then the control panel will be able to control all
the destinations listed in that Set. Depending on the contents of the set, this
would allow for full-matrix or multi-bus control. The source of the destina-
tion name is the Switcher Output table.

Out Panel

- This column is not used for Soft Panels.

Level Set

- Select the CP Level Set name.

Override

- Not used for Soft Panels.

Sequence

- A Sequence Set can be created and named, which, when assigned

to a panel, makes the sequences in that set available on that panel.