Figure 4-9 – Grass Valley CopperHead Pro User Manual
Page 50

44
Camera Unit and Power Supply Installation
Fiber Connections between the Base Station and Camera Unit
Fig. 4-9: Two-Wire Intercom Configuration Dip Switches
Fiber Connections between the Base Station and Camera Unit
The following table summarizes the various fiber cable connection options between the
CopperHead Pro Base Station and Camera Unit.
• The external MPS power supply must be equipped with the required fiber cable
connectors depending on your system requirements. See
on page 28 for a description of the various options.
• The external HDX Power Supply provides two ST Fiber Connectors for connection
between the HDX and Base Station and a SMPTE 304M Connector for connection
between the HDX and Camera Unit.
The following fiber connection scenarios do not take into account any customized cable
and connector installations you may have at your facility. For assistance regarding more
complex connection situations, contact Grass Valley (see
local authorized dealer.
Cable Type
Base Station Power Camera Unit Power
Distance Range Between
Camera and Base
Tactical Fiber
12VDC
Local Battery or AC
Power
Up to 10 KM
SMPTE Hybrid
Fiber
120/220VAC with
Internal Camera
Power Supply
PowerWafer
Adaptor
240 meters
SMPTE Hybrid
Fiber
External MPS Power
Supply 95 Watts1
PowerWafer
Adaptor
5 KM between base and
power supply
240 meters between power
supply and camera
SMPTE Hybrid
Fiber
External HDX Power
Supply - 150 Watts2
PowerPlus Adaptor
5 KM between base and
power supply
3.2 KM between power
supply and camera