Verifying and diagnosing transceiver modules, Verifying transceiver modules, Diagnosing transceiver modules – H3C Technologies H3C SecPath L1000-A Load Balancer User Manual
Page 53
45
System Temperature information (degree centigrade):
--------------------------------------------------------------------------------
---------
Sensor Temperature LowerLimit Warning-UpperLimit Alarm-UpperLimit Shutdown-U
pperLimit
hotspot 1 24 0 70 NA NA
hotspot 2 53 0 80 NA NA
Table 13 Command output
Field Description
Sensor
Temperature sensor.
Hotspot indicates a hot-spot temperature sensor.
Temperature Current
temperature
LowerLlimit
Lower limit of temperature
Warning-UpperLimit
Warning temperature threshold.
Alarm-UpperLimit
Alarm temperature threshold.
Shutdown-UpperLimit
Shut-down temperature threshold.
The L1000-A is automatically shut down when the temperature exceeds the
shutdown upper limit.
Verifying and diagnosing transceiver modules
Verifying transceiver modules
To verify transceiver modules, you can use the display transceiver interface command to display the key
parameters of the transceiver modules, including transceiver module type, connector type, central
wavelength of the laser sent, transfer distance, and vendor name.
To display the transceiver module information:
Task Command
Remarks
Display key parameters of the
transceiver module in a
specified interface.
display transceiver interface
[ interface-type interface-number ]
Available for all transceiver
modules.
Diagnosing transceiver modules
The L1000-A provides the alarm function for transceiver modules for diagnosis.
To display the alarm information about transceiver modules: