Displaying the adjacency table, Troubleshooting ipv6 basics configuration, Symptom – H3C Technologies H3C S12500 Series Switches User Manual
Page 141: Solution

128
--- 2001::15B:E0EA:3524:E791 ping6 statistics ---
1 packet(s) transmitted, 1 packet(s) received, 0.0% packet loss
round-trip min/avg/max/std-dev = 5.404/5.404/5.404/0.000 ms
The output shows that Switch B can ping Switch A and the host. The host can also ping Switch B and
Switch A.
125B
Troubleshooting IPv6 basics configuration
279B
Symptom
An IPv6 address cannot be pinged.
280B
Solution
1.
Use the display ipv6 interface command in any view to verify that the IPv6 address of the output
interface is correct and the interface is up.
2.
Use the debugging ipv6 packet command in user view to enable the debugging for IPv6 packets
to locate the fault.
This manual is related to the following products:
- H3C SR8800 H3C SR6600-X H3C SR6600 H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C WX3000 Series Unified Switches H3C LSWM1WCM10 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module H3C S6800 Series Switches H3C S3100V2 Series Switches H3C S12500-X Series Switches H3C S9800 Series Switches