4 personal computer and serial printer cable, 5 bnc for the vcr trigger and alarm reset, 6 relay and alarm connectors – Eneo EKR-32/8 User Manual
Page 79

2.2.4
Personal computer and serial printer cable
Connect the personal computer or serial printer using a standard complete male/female 9-pin serial cable
(serial extension).
2.2.5
BNC for the VCR Trigger and Alarm Reset
The VCR trigger is described in section 4.1.1 Trigger signal, page 25.
The Alarm Reset trigger is described in section 3.4.14.3 External Alarm Reset Trigger, page 22.
2.2.6
Relay and alarm connectors
Pin
DB25 A
DB25 B
CATEGORY
Pin
DB25 A
DB25 B
CATEGORY
1
Alarm 1
Alarm 17
14
Alarm 14
Alarm 30
2
Alarm 2
Alarm 18
15
Alarm 15
Alarm 31
ALARMS
3
Alarm 3
Alarm 19
16
Alarm 16
Alarm 32
4
Alarm 4
Alarm 20
17
Common al.
Common al.
5
Alarm 5
Alarm 21
18
Relay 1A
Relay 5A
6
Alarm 6
Alarm 22
ALARMS
19
Relay 1B
Relay 5B
7
Alarm 7
Alarm 23
20
Relay 2A
Relay 6A
8
Alarm 8
Alarm 24
21
Relay 2B
Relay 6B
RELAYS
9
Alarm 9
Alarm 25
22
Relay 3A
Relay 7A
10
Alarm 10
Alarm 26
23
Relay 3B
Relay 7B
11
Alarm 11
Alarm 27
24
Relay 4A
Relay 8A
12
Alarm 12
Alarm 28
25
Relay 4B
Relay 8B
13
Alarm 13
Alarm 29
2.2.6.1
Electrical specifications of the alarms
Warning! Do not power the alarm contacts! The sensors (or the alarm control centre) must
supply a dry contact.
2.2.6.2
Electrical specifications for the relays
Switching power: 10W max
Switching voltage: 50 VAC/DC max.
Switching current: 0.5A max
•
2. System installation
Page 11/65
MNNCEKR328_0439