C107e, C207e – Eneo EKR-32/8 User Manual
Page 110

•
c7E
: selects camera 7 on the matrix to which the keyboard is connected (SLAVE1 and
SLAVE2 respectively)
KMaster Operator:
•
c7E
: selects camera 7 on the MASTER matrix
•
c107E
: selects camera 7 on the SLAVE1 matrix
•
c207E
: selects camera 7 on the SLAVE2 matrix.
7.6.5
Master/slave video connection
The video OUT connectors from the slave matrixes should correspond to a precise order of IN connectors
on the master. Follow the indications in the table below when making the connections:
Slave
Slave OUT
Master IN
1
5
29
1
6
30
1
7
31
1
8
32
2
5
25
2
6
26
2
7
27
2
8
28
3
5
21
3
6
22
3
7
23
3
8
24
4
5
17
4
6
18
4
7
19
4
8
20
7.6.6
Setting up the matrixes
In menu 2.1.4 Setup system/Video and installation/Setup set MASTER or SLAVE for each of
the matrixes in the installation; it is necessary to define ID numbers for the slaves. Any installation can only
have one master matrix.
Connect the matrixes on a single RS485 line using the AUXA connector. The connector is no longer
available for controlling devices in cascade with respect to the matrix. The AUXA connectors of the two
matrixes at the ends of the line should be loaded.
•
7. Appendix 2: composite installations
Page 42/65
MNNCEKR328_0439