Sensitivity

This item is used to set the sensitivity of detection grids for the camera. A

greater value indicates more sensitive motion detection. A motion alarm

will be triggered once the amount of motion detected exceeds the

Threshold value.

Move the cursor to and press ENTER, and then use UP/

DOWN keys to adjust the value. The value is increased by 4% increment.

-

Block Threshold

indicates the motion alarm triggered level; select from

<1> to <16>. Selecting <1> means the DVR will trigger the alarm when

one grid is detected; and selecting <16> means the DVR will trigger the

alarm when 16 grids are detected. Move the cursor to

and press ENTER, and then use UP / DOWN keys to adjust the value.

„ Alarm In

This item allows users to enable/ disable alarm input detection. According to users’

application, select (Normal Open) or (Normal Close) to enable the

alarm input detection, or select to disable the detection.

If is selected without installing any device, an alarm will be triggered and the

Event Icon will always display on the monitor until the selection is changed to

or , or when a device is installed.

„ Alarm Out

This item allows users to enable / disable the alarm output on the selected channel

to activate the relay. The signal can be a light or siren to caution an alarm event.

Select to enable the alarm output, or to disable.