beautypg.com

Maintain configuration – Welltech WG5260 V.6.2 User Manual

Page 58

background image

Welltech Computer Co., Ltd.

WellGate 5260 User Guide – V6.2.0

- 58 -

depending on the switches. When this bit is not set, then the default
PRI interface type applies (E1 for ETSI).

- CC_USE_E1_PRI bit: When this bit is set, the PRI interface type is

forced to E1 (=30B+D) rather than T1 (=23B+D) for USA variants.
This is usable in Taiwan, where E1 and T1 lines can be used
depending on the switches on E1 lines. When this bit is not set, then
the default PRI interface type applies (E1 for ETSI).

- CC_START_WITH_B_CHAN_OOS bit: When this bit is set, the B-

channels are started in the Out-Of-Service state (OOS), not in the In-
Service state (IS). They are not available for call processing until
brought back In-Service through a Restart message. This is useful
on US PRI lines that start in OOS state by default and can also be
useful for Fractional PRI lines.

- CC_CHAN_ALLOC_LOWEST bit: When this bit is set, CC allocates

B-channels starting from the lowest available B-channel ID. When
the CC_CHAN_ALLOC_LOWEST bit is set, the
CC_REVERSE_CHAN_ALLOC_ALGO and
CC_CHAN_ALLOC_HIGHEST bits are ignored.

- CC_CHAN_ALLOC_HIGHEST bit: When this bit is set, CC allocates

B-channels starting from the highest available B-channel ID. When
the CC_CHAN_ALLOC_HIGHEST bit is set, the
CC_REVERSE_CHAN_ALLOC_ALGO bit is ignored.

• Trans Cap: Transfer Capability

- Voice

Service

- Data

Service

- Modem

Service

• Call ID Transfer Type: Call ID transfer type

- Disable Caller ID: default parameter
- Transparent Caller ID
- Relay Caller ID
- Bypass Caller ID

• Line Build Parameters: The first parameter is the line build-out loss. The

parameter is applicable only to T1 trunks. The overwrite parameter
(default = 0; no overwrite) enables users to write to the 3 Pulse Mask
(XPM) registers, thus controlling the trunk analog pulse shape
(applicable to E1 and T1 trunks):
- Line Build LOSS: (applicable only to T1 trunks) this parameter is

used to control the loss for different lengths of the line: 0 dB, -7.5 dB,
-15 dB, or -22.5 dB.

- Line

Build

Overwrite:

The overwrite parameter, which is zero by

default (no overwrite), enables Users to write to the 3 Pulse Mask
(XPM) registers, thus controlling the Trunk analog pulse shape
(applicable to E1 and T1 trunks).

- Line Build XPM 0,1 and 2: Pulse Mask (XPM) registers 0-2

Maintain Configuration
Reset a channel or a trunk to idle state and block or unblock a channel or a
trunk.
Start Path: Configuration>Interface>Detail>Maintain