Welltech WG5260 V.6.2 User Manual
Page 56

Welltech Computer Co., Ltd.
WellGate 5260 User Guide – V6.2.0
- 56 -
o
0x00020000: Only applicable when configuration is N12, QSIG or
ETSI. If this bit is set, the call is cleared on reception of STATUS with
incompatible state. Otherwise, no action is taken
• Q.931 Incoming Opt.: used for Q.931 incoming call behavior
o
0x00000010: Automatic answering on TELEPHONY incoming calls︰
When this bit is set, Board sends a CONNECT (answer) message on
TELEPHONY incoming calls.
o
0x00000020: Automatic answering on NOT TELEPHONY incoming
calls: When this bit is set, Board sends a CONNECT (answer)
message on NOT TELEPHONY incoming calls.
o
0x00000800: When this bit is set, the ISDN Stack forces the sending
of the Channel-id Information Element in the first response to an
incoming call indication. When this bit is not set, The ISDN Stack
forces it only if it is mandatory for the running operator, or if on NT-
side. This have been identified as solving a problem with Coral PBX
that requests a Channel in the first respond to an incoming call from
it .
o
0x00001000: When this bit is set, the ISDN Stack does NOT
automatically generate a Setup Ack. When this bit is not set, the
ISDN Stack sends a Setup Ack when it detects overlap receiving in
progress.
o
0x00002000: When this bit is set, the ISDN Stack forces the sending
of Channel-id Information Element (IE) in the Call-Proceeding
message. When this bit is not set, the ISDN Stack forces it only if it is
mandatory for the running operator or if on NT-side.
o
0x00010000: When this bit is set, the board automatically sends a
Progress-Indicator #8 (“in-band tones/announcements available”) in
the Setup-Ack message that is sent back automatically by the board
when it receives and accepts a Setup message in overlap-receiving
mode (e.g no digit in the Setup), for Voice calls only (BC encoded as
Speech or 3.1-Audio). This enables tone generation to the Terminals
after handset off-hook.
• Q.931 Outgoing Opt.: Used for Q.931 outgoing call behavior
- 0x00000002: Automatic generation of ‘Sending-complete’
information element in SETUP (as result of Place Call).When this
bit is set, Board does not generate automatically the 'Sending-
complete' information element in the SETUP. The User application
must request it in the Place Call function. Otherwise (if this bit is not
set), the Board generates it automatically in the SETUP message
only.
- 0x00000010: use Mu-law if this bit is set, or A-law will be used.
Apply only for Korea variance, you can OR the required option
together
- 0x00000080: When this bit is set, ISDN stack uses the KEYPAD IE
to store the called number digits instead of the CALLED_NB IE. Only
is applicable for KOR variant (Korean network). That is Useful for
Korean switches do not accept the Called number IE.
- 0x00000100: When this bit is set, ISDN Stack forces the sending of
a Channel-id IE in an outgoing SETUP message even if it is not
required by the standard(i.e., it is optional only ), and no Channel-id