beautypg.com

Wavetronix Command Collector (CMD-DCx) - User Guide User Manual

Page 57

background image

56

CHAPTER 5 SENSOR CONFIGURATION PAGE

˽

Custom ID – Allows you to change the custom text displayed for this sensor. This field

is optional and is provided purely for additional identification information for each

sensor.

˽

Collection Interval (sec) – Allows you to enter the interval of time between Collector’s

attempts to connect and download data for this sensor. By default, this is the same as

the sensor interval. If you would like to change this setting, uncheck the Use Sensor

Interval checkbox.
If communication to the sensor’s IP/port is inconsistent, setting a lower collection in-

terval may give Collector multiple chances at connecting and retrieving each data bin

from the sensor.

If communication to the sensor has very high latency or other overhead, setting a high-

er collection interval will allow Collector to make fewer connections and to efficiently

retrieve more data packets per connection.

˽

Sensor Interval (sec) – Shows the currently set sensor interval time, which indicates

how often the sensor is collecting data.

Note

System administrators may need to experiment with different sensor and collection
interval combinations for the most optimal configuration for each sensor.

˽

Time Zone – Allows you to set the time zone for the sensor.

˽

DST – Allows you to choose whether or not the sensor will observe daylight savings time.

˽

Sensor Networks – Contains each network registered on Collector. Checking a net-

work box will add the sensor to that network.

˽

Use Advanced Collection Interval – Provides a way to schedule collection jobs to hap-

pen when needed. Checking this box will open the Advanced Collection Interval tabs.
The Basic tab allows you to enter a number and select the time units (seconds, minutes,

hours) to be used as the advanced collection interval (see Figure 5.7). Once you’ve set

the interval, click the Add button and the new collection interval will appear beneath

the box.

Figure 5.7 – Basic Tab

The Advanced tab allows you to set a start and end date, as well as a start time, for collection

(see Figure 5.8). If you don’t check the box next to the end date, the job will indefinitely con-

tinue to run as scheduled. The tabs under the Repeat section can be used to set how often