CHAPTER 7 • SYSTEM PAGE

99

Click the Export Sensors button to take a snapshot of some or all of the current sensors

registered in Collector and output it to XML format. After clicking Export Sensors, a link

will appear allowing you to save the XML file to the local machine as a sensor configuration

backup.

Selecting All will export all current sensors in the system. To select only a subset of Col-

lector sensors, choose the Manual Select option to open a tree control showing all the

Collector sensors organized by network and collection status. Check the sensors to export

in the tree and click Export Sensors to create the XML file with only the selected sensors

included.

Note

Because of the different categories, each sensor will likely be listed in the tree in
multiple locations. Checking multiple boxes for the same sensor will have no effect-
-the XML output will only contain one entry for that sensor.

Collector supports two kinds of XML formats for sensor export: Simple and Full. Simple

XML contains the following small subset of sensor information:

˽

Sensor Type

˽

IP Address

˽

Port

˽

Multidrop ID

˽

Custom ID

˽

Location

˽

Description

˽

Collector ID

Full XML contains all sensor information including custom properties and driver information.

For Collector backup purposes, use the Full XML export option to ensure all sensor con-

figuration information is persisted. Use the Simple XML export if basic information about

the sensors currently registered in Collector is needed for other systems or applications.

The Import Collector Sensors box allows you to upload a previously saved sensor configu-

ration XML file to Collector. Uploading a sensor XML file for a sensor that already exists

will not create a duplicate of the current sensor configuration.